{"id":31725,"date":"2026-11-19T08:37:13","date_gmt":"2026-11-19T08:37:13","guid":{"rendered":"https:\/\/www.vincervalve.com\/?p=31725"},"modified":"2026-11-19T08:45:08","modified_gmt":"2026-11-19T08:45:08","slug":"3-way-ball-valve-how-it-works-l-port-vs-t-port-diagrams","status":"publish","type":"post","link":"https:\/\/www.vincervalve.com\/fi\/3-way-ball-valve\/","title":{"rendered":"3-Way Ball Valve: How It Works, L-Port vs T-Port &amp; Diagrams"},"content":{"rendered":"<!-- VINCER 3-way ball valve article: paste the entire snippet into a Custom HTML block or Elementor HTML widget. The WordPress post title supplies H1. -->\n<div class=\"vincer-blog\">\n<style>\n\/* Scoped styles: only affect this article *\/\n.vincer-blog {\n  --vb-accent: #0666C4;\n  --vb-accent-dark: #002174;\n  --vb-body: #333333;\n  --vb-muted: #54595F;\n  --vb-border: #CDD5DE;\n  --vb-tint: #F3F9FF;\n  --vb-prose: 720px;\n  box-sizing: border-box;\n  max-width: 100%;\n  padding: 24px;\n  background: #fff;\n  color: var(--vb-body);\n  font-family: \"Poppins\", Arial, sans-serif;\n  font-size: 16px;\n  font-weight: 400;\n  line-height: 1.75;\n}\n.vincer-blog, .vincer-blog * { box-sizing: border-box; }\n.vincer-blog .vb-article { max-width: var(--vb-prose); margin: 0 auto; }\n.vincer-blog p { margin: 0 0 1.15em; overflow-wrap: break-word; }\n.vincer-blog .vb-lead { font-size: 17px; line-height: 1.75; }\n.vincer-blog h2, .vincer-blog h3 { color: #101820; letter-spacing: -.015em; }\n.vincer-blog h2 { margin: 48px 0 18px; font-size: 34px; font-weight: 500; line-height: 1.25; }\n.vincer-blog h3 { margin: 32px 0 12px; font-size: 23px; font-weight: 500; line-height: 1.35; }\n.vincer-blog strong { font-weight: 600; }\n.vincer-blog a { color: var(--vb-accent); text-decoration: underline; text-underline-offset: 2px; overflow-wrap: anywhere; }\n.vincer-blog a:hover { color: var(--vb-accent-dark); }\n.vincer-blog ul, .vincer-blog ol { padding-left: 1.55em; margin: 0 0 1.4em; }\n.vincer-blog li { margin-bottom: .55em; }\n.vincer-blog .vb-figure { margin: 28px 0 32px; }\n.vincer-blog .vb-figure img { display: block; width: 100%; height: auto; border-radius: 10px; border: 1px solid #E3E9F0; }\n.vincer-blog .vb-figure figcaption { margin-top: 10px; text-align: center; font-size: 13px; line-height: 1.55; color: var(--vb-muted); }\n.vincer-blog .vb-note { background: var(--vb-tint); border: 1px solid var(--vb-border); border-left: 4px solid var(--vb-accent); border-radius: 10px; padding: 16px 20px; margin: 24px 0 32px; }\n.vincer-blog .vb-table-block { max-width: 100%; margin: 28px 0 36px; }\n.vincer-blog .vb-table-scroll { display: block; width: 100%; max-width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch; overscroll-behavior-x: contain; scrollbar-width: thin; scrollbar-color: #90A8C5 #EFF4F9; border-radius: 8px; }\n.vincer-blog .vb-table-scroll:focus-visible { outline: 3px solid var(--vb-accent); outline-offset: 3px; }\n.vincer-blog .vb-data-table { width: 100%; border-collapse: collapse; border-spacing: 0; background: #fff; font-size: 14px; line-height: 1.55; table-layout: auto; }\n.vincer-blog .vb-data-table th { background: var(--vb-accent-dark); color: #fff; text-align: left; font-weight: 600; padding: 13px 14px; border: 1px solid var(--vb-accent-dark); vertical-align: middle; }\n.vincer-blog .vb-data-table td { background: #fff; color: var(--vb-body); text-align: left; font-weight: 400; padding: 13px 14px; border: 1px solid var(--vb-border); vertical-align: top; overflow-wrap: break-word; }\n.vincer-blog .vb-data-table tbody tr:nth-child(even) td { background: #F8FBFE; }\n.vincer-blog .vb-data-table td:first-child { font-weight: 600; }\n.vincer-blog .vb-table-hint { display: none; margin: 8px 0 0; font-size: 12px; color: var(--vb-muted); text-align: right; }\n.vincer-blog .vb-steps-card { background: var(--vb-tint); border: 1px solid var(--vb-border); border-radius: 12px; padding: 22px 24px; margin: 20px 0 24px; }\n.vincer-blog .vb-steps { list-style: none; padding: 0; margin: 0; counter-reset: vb-step; }\n.vincer-blog .vb-steps li { counter-increment: vb-step; display: flex; gap: 12px; align-items: flex-start; margin-bottom: 18px; }\n.vincer-blog .vb-steps li:last-child { margin-bottom: 0; }\n.vincer-blog .vb-steps li:before { content: counter(vb-step); display: inline-flex; flex: 0 0 27px; width: 27px; height: 27px; align-items: center; justify-content: center; border-radius: 50%; background: var(--vb-accent-dark); color: #fff; font-size: 13px; font-weight: 600; margin-top: 1px; }\n.vincer-blog .vb-cta { background: var(--vb-accent-dark); color: #fff; border-radius: 12px; padding: 28px; margin: 42px 0 28px; }\n.vincer-blog .vb-cta .vb-cta-title { color: #fff; font-size: 23px; font-weight: 600; margin: 0 0 12px; }\n.vincer-blog .vb-cta .vb-cta-text { color: #F4F7FD; margin: 0 0 22px; }\n.vincer-blog .vb-cta .vb-cta-button { display: inline-block; background: #fff; color: var(--vb-accent-dark); text-decoration: none; font-size: 15px; line-height: 1.3; font-weight: 600; border-radius: 50px; padding: 13px 20px; }\n.vincer-blog .vb-cta .vb-cta-button:hover { background: #EAF3FF; color: var(--vb-accent-dark); }\n@media (max-width: 767px) {\n  .vincer-blog { padding: 16px 10px; font-size: 16px; line-height: 1.7; }\n  .vincer-blog .vb-lead { font-size: 16px; }\n  .vincer-blog h2 { font-size: 25px; margin-top: 34px; margin-bottom: 14px; }\n  .vincer-blog h3 { font-size: 20px; margin-top: 26px; margin-bottom: 10px; }\n  .vincer-blog .vb-data-table { min-width: 640px; font-size: 14px; }\n  .vincer-blog .vb-data-table th, .vincer-blog .vb-data-table td { padding: 11px 12px; }\n  .vincer-blog .vb-table-hint { display: block; }\n  .vincer-blog .vb-steps-card { padding: 17px 16px; }\n  .vincer-blog .vb-cta { padding: 22px 18px; }\n  .vincer-blog .vb-cta .vb-cta-title { font-size: 21px; }\n  .vincer-blog .vb-cta .vb-cta-button { text-align: center; width: 100%; }\n}\n\n<\/style>\n<article class=\"vb-article\">\n\n<p class=\"vb-lead\">A <strong>3-way ball valve<\/strong> uses a rotating ball to direct fluid between three pipe connections. The two common internal passages are <strong>L-portti<\/strong> ja <strong>T-port<\/strong>. An L-port valve is typically used to switch between two flow paths, while a T-port design can also connect three ports in certain positions. Understanding these flow patterns is the first step in choosing the right valve for diverting, combining or switching applications.<\/p>\n<p>This guide explains the operating principle with diagrams and compares manual, electric and pneumatic 3-way ball valves for industrial piping systems.<\/p>\n<h2>What Is a 3-Way Ball Valve?<\/h2>\n<p>A 3-way ball valve has three pipe connections and a spherical ball with a passage through it. Turning the valve stem changes how the passage aligns with the ports, allowing fluid to move through selected connections.<\/p>\n<p>Compared with a standard 2-way ball valve, a 3-way design offers more ways to route fluid within a piping system. It can be used to select between two pipelines or connect multiple lines, depending on the passage inside the ball.<\/p>\n<p>The shape of that passage is the main distinction between an L-port and a T-port valve.<\/p>\n<h2>How Does a 3-Way Ball Valve Work?<\/h2>\n<p>The ball rotates inside the valve body. As the handle or actuator moves the stem, the opening inside the ball aligns with different ports and creates a flow path through the valve.<\/p>\n<p>For example, in a common switching arrangement, the bottom connection serves as a shared line. One position connects it to the left branch; another connects it to the right branch. A different internal passage can provide additional connections between the three ports.<\/p>\n<p><strong>The ball design determines the available flow paths.<\/strong> The operating method\u2014manual, electric or pneumatic\u2014determines how the ball is turned.<\/p>\n<h2>L-Port vs T-Port: Flow Patterns and Diagrams<\/h2>\n<p>The following VINCER diagram illustrates common <strong>L-pattern and T-pattern flow paths<\/strong> in three-way ball valves. The arrows show the connected flow passages in the illustrated configurations.<\/p>\n<figure class=\"vb-figure\"><a aria-label=\"Open full-size VINCER three-way ball valve flow diagram\" href=\"https:\/\/www.vincervalve.com\/wp-content\/uploads\/2026\/11\/3-way-ball-valve-flow-direction-1-e1794973169279.webp\" rel=\"noopener noreferrer\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" alt=\"VINCER three-way ball valve L-port and T-port flow pattern diagrams\" height=\"543\" src=\"https:\/\/www.vincervalve.com\/wp-content\/uploads\/2026\/11\/3-way-ball-valve-flow-direction-1-e1794973169279.webp\" width=\"768\"><\/a><figcaption>Typical L-port and T-port flow patterns. Source: VINCER. <a href=\"https:\/\/www.vincervalve.com\/wp-content\/uploads\/2026\/11\/3-way-ball-valve-flow-direction-1-e1794973169279.webp\" rel=\"noopener noreferrer\" target=\"_blank\">View full diagram<\/a><\/figcaption><\/figure>\n\n<h3>L-Port 3-Way Ball Valve Flow Patterns<\/h3>\n<p>Yksi <strong>L-port 3-way ball valve<\/strong> has an L-shaped passage through the ball. It commonly connects one shared port to either of the other two ports, making it suitable for selecting between two branches.<\/p>\n<p>In the <strong>L-pattern illustration (E)<\/strong>, one flow path connects the bottom and right ports; the other connects the bottom and left ports. This is a simple way to direct a single supply line toward one of two destinations.<\/p>\n<p>L-port configurations are commonly used for <strong>flow diversion and line switching<\/strong> in water treatment equipment, utilities and process piping.<\/p>\n<h3>T-Port 3-Way Ball Valve Flow Patterns<\/h3>\n<p>A <strong>T-port 3-way ball valve<\/strong> has a T-shaped passage that provides additional routing options. As shown in the <strong>T-pattern illustrations (A\u2013D)<\/strong>, typical connections include left-to-right flow, a side port connected to the bottom port, and a configuration connecting all three ports.<\/p>\n<p>These arrangements make T-port valves useful when a system needs to combine two streams, divert flow or maintain a connection between multiple pipeline branches.<\/p>\n<h3>L-Port vs T-Port: Key Differences<\/h3>\n<div class=\"vb-table-block\"><div aria-label=\"L-port versus T-port flow pattern comparison\" class=\"vb-table-scroll\" role=\"region\" tabindex=\"0\"><table class=\"vb-data-table\">\n<thead>\n<tr>\n<th>Ominaisuus<\/th>\n<th>L-Port<\/th>\n<th>T-Port<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Internal passage<\/td>\n<td>L-shaped<\/td>\n<td>T-shaped<\/td>\n<\/tr>\n<tr>\n<td>Typical flow function<\/td>\n<td>Switch between two paths<\/td>\n<td>Switch, combine or connect multiple paths<\/td>\n<\/tr>\n<tr>\n<td>Three ports connected together<\/td>\n<td>Not a normal L-port switching function<\/td>\n<td>Available in a T-port flow pattern<\/td>\n<\/tr>\n<tr>\n<td>Common use<\/td>\n<td>Selecting one of two branches<\/td>\n<td>Combining streams, bypass and multi-line routing<\/td>\n<\/tr>\n<tr>\n<td>Main selection question<\/td>\n<td>Which branch should connect to the shared line?<\/td>\n<td>Which two or three ports should be connected?<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div><p aria-hidden=\"true\" class=\"vb-table-hint\">\u2194 Swipe left or right to see the full table<\/p><\/div>\n<div class=\"vb-note\"><strong>Selection tip: <\/strong>For a practical specification, start with a simple sketch of the connections you need rather than choosing solely by the L-port or T-port name.<\/div>\n<h2>Diverting, Combining and Mixing: Which Configuration Fits?<\/h2>\n<p>Three-way ball valves are often used to route fluid between lines. The required process function helps determine which flow pattern is most appropriate.<\/p>\n<p><strong>Flow diverting.<\/strong> In a water-treatment system with two filter branches, an L-port valve can switch the supply from one filter line to the other. The valve acts as a route selector within the piping system.<\/p>\n<p><strong>Flow combining.<\/strong> If two supply lines need to feed one common outlet, a T-port pattern that connects all three ports can provide the required passage. This arrangement can be useful in water and general process piping.<\/p>\n<p><strong>Mixing.<\/strong> A T-port valve can bring two compatible fluid streams together. However, combining two streams does not by itself provide accurate control of their mixing ratio or outlet temperature. Applications requiring proportional mixing need a suitable control arrangement.<\/p>\n<div class=\"vb-note\"><strong>Selection tip: <\/strong>The key question is straightforward: <strong>Do you need to select one branch, connect two lines, or connect all three ports?<\/strong> The answer guides the choice of internal flow pattern.<\/div>\n<h2>Manual vs Electric vs Pneumatic 3-Way Ball Valves<\/h2>\n<p>The internal L-port or T-port passage determines how fluid can be routed. The operating method determines how the valve changes position. Manual, electric and pneumatic options can be considered for the same general flow-control purposes, with different operating requirements.<\/p>\n<h3>Manual 3-Way Ball Valves<\/h3>\n<p>Manual valves use a handle or lever to turn the ball. They suit pipelines where flow paths are changed locally and automatic operation is unnecessary. Their simple operating method is useful for occasional switching, maintenance arrangements and general utility lines.<\/p>\n<p>See VINCER&#8217;s <a href=\"https:\/\/www.vincervalve.com\/fi\/manual-ball-valves\/\">manual ball valve range<\/a> for related valve options.<\/p>\n<figure class=\"bd-fig\" style=\"text-align: center; margin: 24px 0 32px;\">\n  <img decoding=\"async\" src=\"https:\/\/www.vincervalve.com\/wp-content\/uploads\/2024\/07\/Ball-Valve-Types4.webp\" alt=\"VINCER Manual 3-way Flanged Ball Valve\" loading=\"lazy\" style=\"display: block; width: 100%; max-width: 300px; height: auto; object-fit: contain; margin: 0 auto; border-radius: 8px;\">\n<\/figure>\n<h3>Electric 3-Way Ball Valves<\/h3>\n<p>Electric 3-way ball valves use an electric actuator to turn the ball and change the flow path. They suit remote operation and equipment integrated into an electrical control system.<\/p>\n<p>For example, VINCER offers an <a href=\"https:\/\/www.vincervalve.com\/fi\/products\/electric-threaded-ball-valves\/\">electric threaded 3-way ball valve, VK-10T3<\/a>, for automated flow-switching applications.<\/p>\n<figure class=\"bd-fig\" style=\"text-align: center; margin: 24px 0 32px;\">\n  <img decoding=\"async\" src=\"https:\/\/www.vincervalve.com\/wp-content\/uploads\/2026\/07\/electric-threaded-3-way-ball-valve-vincer.webp\" alt=\"VINCER electric threaded 3-way ball valve\" loading=\"lazy\" style=\"display: block; width: 100%; max-width: 370px; height: auto; object-fit: contain; margin: 0 auto; border-radius: 8px;\">\n<\/figure>\n<h3>Pneumatic 3-Way Ball Valves<\/h3>\n<p>Pneumatic 3-way ball valves use compressed air to drive an actuator. They can provide fast switching and are well suited to applications that require quick or frequent flow changes.<\/p>\n<p>They are also a practical option where electric actuation is impractical, provided a suitable compressed air supply and control system are available.<\/p>\n<p>VINCER:n <a href=\"https:\/\/www.vincervalve.com\/fi\/products\/pneumatic-flanged-ball-valves\/\">pneumatic flanged 3-way ball valve, AT-10F3<\/a>, is one example for automated flow switching in industrial piping systems.<\/p>\n<figure class=\"bd-fig\" style=\"text-align: center; margin: 24px 0 32px;\">\n  <img decoding=\"async\" src=\"https:\/\/www.vincervalve.com\/wp-content\/uploads\/2026\/07\/pneumatic-3-way-flanged-ball-valve-vincer.webp\" alt=\"VINCER pneumatic flanged 3-way ball valve\" loading=\"lazy\" style=\"display: block; width: 100%; max-width: 400px; height: auto; object-fit: contain; margin: 0 auto; border-radius: 8px;\">\n<\/figure>\n<div class=\"vb-table-block\"><div aria-label=\"Manual electric and pneumatic valve operation comparison\" class=\"vb-table-scroll\" role=\"region\" tabindex=\"0\"><table class=\"vb-data-table\">\n<thead>\n<tr>\n<th>Operating method<\/th>\n<th>Main operating requirement<\/th>\n<th>Typical selection reason<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>K\u00e4ytt\u00f6opas<\/td>\n<td>Local handle operation<\/td>\n<td>Simple, occasional on-site switching<\/td>\n<\/tr>\n<tr>\n<td>S\u00e4hk\u00f6inen<\/td>\n<td>Electrical power and compatible controls<\/td>\n<td>Remote operation and integration with electrical control systems<\/td>\n<\/tr>\n<tr>\n<td>Pneumaattinen<\/td>\n<td>Compressed air supply and suitable controls<\/td>\n<td>Fast switching or applications where electric actuation is impractical<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div><p aria-hidden=\"true\" class=\"vb-table-hint\">\u2194 Swipe left or right to see the full table<\/p><\/div>\n<h2>How to Select a 3-Way Ball Valve<\/h2>\n<p>Choosing a 3-way ball valve starts with understanding how fluid needs to flow through your system. Here are three simple things to consider:<\/p>\n<style>\n.vincer-selection-steps {\n  background: #F3F9FF;\n  border: 1px solid #CDCDCD;\n  border-radius: 12px;\n  padding: 24px;\n  margin: 24px 0 32px;\n}\n\n.vincer-selection-item + .vincer-selection-item {\n  border-top: 1px solid #D0DCEA;\n  margin-top: 24px;\n  padding-top: 24px;\n}\n\n.vincer-selection-heading {\n  display: flex;\n  align-items: center;\n  gap: 12px;\n  margin-bottom: 12px;\n}\n\n.vincer-selection-number {\n  flex: 0 0 36px;\n  width: 36px;\n  height: 36px;\n  display: flex;\n  align-items: center;\n  justify-content: center;\n  border-radius: 50%;\n  background: #002174;\n  color: #FFFFFF;\n  font-weight: 600;\n}\n\n.vincer-selection-title {\n  flex: 1;\n  min-width: 0;\n  font-size: 18px;\n  font-weight: 600;\n  line-height: 1.4;\n  color: #222222;\n}\n\n.vincer-selection-item p {\n  margin: 0;\n  line-height: 1.7;\n}\n\n@media (max-width: 768px) {\n  .vincer-selection-steps {\n    padding: 16px;\n  }\n  .vincer-selection-title {\n    font-size: 16px;\n  }\n}\n<\/style>\n\n<div class=\"vincer-selection-steps\">\n\n  <div class=\"vincer-selection-item\">\n    <div class=\"vincer-selection-heading\">\n      <span class=\"vincer-selection-number\">1<\/span>\n      <span class=\"vincer-selection-title\">\n        Inlets, Outlets and Flow Direction\n      <\/span>\n    <\/div>\n    <p>\n      How many inlet and outlet pipes are connected?\n      Do you want to switch between two lines or\n      connect multiple lines at the same time?\n      Describing the intended flow helps identify\n      a suitable L-port or T-port arrangement.\n    <\/p>\n  <\/div>\n\n  <div class=\"vincer-selection-item\">\n    <div class=\"vincer-selection-heading\">\n      <span class=\"vincer-selection-number\">2<\/span>\n      <span class=\"vincer-selection-title\">\n        Fluid Medium and Pipe Size\n      <\/span>\n    <\/div>\n    <p>\n      What fluid will pass through the valve, and\n      what is the approximate pipe size?\n      These details help us recommend compatible\n      materials and dimensions.\n    <\/p>\n  <\/div>\n\n  <div class=\"vincer-selection-item\">\n    <div class=\"vincer-selection-heading\">\n      <span class=\"vincer-selection-number\">3<\/span>\n      <span class=\"vincer-selection-title\">\n        Operating Method\n      <\/span>\n    <\/div>\n    <p>\n      Do you need a manual handle, electric operation\n      or pneumatic actuation? Consider whether the\n      valve will be switched locally or remotely\n      and how often it needs to operate.\n    <\/p>\n  <\/div>\n\n<\/div>\n\n<p>If you know the operating pressure, temperature or connection type, you can share these details too. They help refine the selection, but you can start with a simple description of your application.<\/p>\n<div class=\"vb-cta\"><h3 class=\"vb-cta-title\">Not Sure Which 3-Way Ball Valve You Need?<\/h3><p class=\"vb-cta-text\">If you are unsure which flow pattern or valve configuration suits your system, VINCER&#8217;s sales engineers can help. Simply describe your application or share a photo or sketch of the piping layout. Our team will review your needs and recommend a suitable configuration.<\/p><a class=\"vb-cta-button\" href=\"https:\/\/www.vincervalve.com\/fi\/contact-us\/\">Contact Our Sales Engineers  \u2192<\/a><\/div>\n\n\n\n<\/article>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>A 3-way ball valve uses a rotating ball to direct fluid between three pipe connections. The two common internal passages are L-port and T-port. An L-port valve is typically used to switch between two flow paths, while a T-port design can also connect three ports in certain positions. Understanding these flow patterns is the first [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":31722,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_titles_title":"3-Way Ball Valve: L-Port vs T-Port & Flow Diagrams | VINCER","_seopress_titles_desc":"See how 3-way ball valves work with L-port and T-port flow diagrams. Compare flow paths, common uses, and manual, electric or pneumatic options.","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"","_seopress_news_disabled":"","_seopress_video_disabled":"","_seopress_video":[],"_seopress_pro_schemas_manual":[],"_seopress_pro_rich_snippets_disable_all":"","_seopress_pro_rich_snippets_disable":[],"_seopress_pro_schemas":[],"footnotes":""},"categories":[12,62,63,13],"tags":[],"class_list":["post-31725","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-actuated-valves","category-blog","category-recent-blog","category-valves"],"acf":[],"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/www.vincervalve.com\/fi\/wp-json\/wp\/v2\/posts\/31725","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.vincervalve.com\/fi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.vincervalve.com\/fi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.vincervalve.com\/fi\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.vincervalve.com\/fi\/wp-json\/wp\/v2\/comments?post=31725"}],"version-history":[{"count":4,"href":"https:\/\/www.vincervalve.com\/fi\/wp-json\/wp\/v2\/posts\/31725\/revisions"}],"predecessor-version":[{"id":31729,"href":"https:\/\/www.vincervalve.com\/fi\/wp-json\/wp\/v2\/posts\/31725\/revisions\/31729"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.vincervalve.com\/fi\/wp-json\/wp\/v2\/media\/31722"}],"wp:attachment":[{"href":"https:\/\/www.vincervalve.com\/fi\/wp-json\/wp\/v2\/media?parent=31725"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.vincervalve.com\/fi\/wp-json\/wp\/v2\/categories?post=31725"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.vincervalve.com\/fi\/wp-json\/wp\/v2\/tags?post=31725"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}